INDUSTRIAL VENTILATION · ATEX GUIDE

Does your installation involve an explosive atmosphere?

Flammable gases, vapours or dust: start with the zoning defined for your site. It guides the equipment and marking to be considered.

Understand the essentials

Visual guide

From risk to the right marking

Follow the path: atmosphere, site zone, equipment category, then marking.

AtmosphereGas · vapours · dust
Site zoneDefined by site zoning
CategoryEquipment property
MarkingCheck it in full

Where and when can it occur?

Choose a medium to see its zone scale.

0
Continuous / frequentor long periods
1G
1
Occasionalduring normal operation
1G · 2G
2
Unlikelyand brief if present
1G · 2G · 3G

The zone describes the location. It comes from the installation zoning document.

Which category should you check?

Category = equipment · G = gas · D = dust

1
1G / 1DHighest level of protection
0 · 20
2
2G / 2DEnhanced level
1 · 21
3
3G / 3DFor Zones 2 / 22
2 · 22
2GD · 3GDCombined marking: verify both gas and dust suitability

Important Product sheets below cover Categories 2 and 3. Zones 0 / 20 require Category 1.

Decode a marking

Select a token to understand its role.

II: equipment intended for surface industries.

LEARNING EXAMPLE · INCOMPLETE FRAGMENT

Motor guide

Which motor marking for each zone?

Start with the zone listed in your site documentation, then check the complete motor nameplate and the conditions in its instructions.

Gas · Zone 0Ga

Very high protection is required. A marking limited to Ex db, Ex eb or Ex ec is not sufficient for this zone.

Gas · Zone 1Gb

Ex db: flameproof enclosure. Ex eb: increased safety. These protection types can correspond to EPL Gb when the certificate covers the motor and its use.

Gas · Zone 2Gc

Ex ec: increased safety for EPL Gc. An EPL Gb motor may also be assessed for Zone 2 when the other parameters match.

Ex db IIC T4 Gb — learning example

Select each element: a real nameplate may include other codes and conditions.

Ex: equipment designed according to one or more explosion protection types.

II 2G · Ex db / Ex eb · GbExamples of gas marking to assess for Zone 1. Selection also depends on the gas subgroup and temperature.
II 3G · Ex ec · GcExample of gas marking to assess for Zone 2. EPL Gb may also be assessed when the complete marking is suitable.
Zone 21 → Db · Ex tb | Zone 22 → Dc · Ex tcFor dust, also check group IIIA / IIIB / IIIC, the maximum surface temperature shown in °C and the IP rating. Zone 20 requires EPL Da.
IIA · IIB · IICGas subgroups, to compare with the actual substance. IIC is the most demanding.
T1 ≤450 °C · T2 ≤300 °C · T3 ≤200 °C · T4 ≤135 °C · T5 ≤100 °C · T6 ≤85 °CMaximum surface temperature for gas classes. The higher the T number, the lower the maximum surface temperature.
IIIA · IIIB · IIIC · T°C · IPFor dust: check the group, surface temperature in °C and ingress protection rating together.
Ta / Tamb · X · UTa/Tamb: permitted ambient range. X: special certificate conditions. U: Ex component that must be integrated according to its certificate.

The markings after the protection code matter too. Check gas or dust group, T / °C, Ta or Tamb (ambient), IP, voltage, frequency, speed and inverter use. Certificate suffix X signals specific conditions; U identifies a component rather than complete equipment. Case matters: db is a gas protection type, while Db is a dust EPL. A motor alone does not certify the assembled fan.

Ex eb, Ex db or Ex ec alone is never enough to select a motor: the complete nameplate, certificate, instructions, gas or dust, ambient temperature and fan assembly must match the application. Have the selection confirmed before ordering.

To assess your application
Documented zoneGas / dust identifiedAirflow · pressure · temperatureMarking and product sheet

These visuals provide general guidance: site zoning comes from the risk assessment, and each item’s complete marking must be checked for the application. Prevention guidance (INRS) ↗

Selection assistant

From site zone to fan + motor marking

Answer five steps. The result separates the target marking for the fan and its motor.

  1. 01Atmosphere
  2. 02Zone
  3. 03Substance
  4. 04Motor
  5. 05Result

1. Which atmosphere is listed in the zoning document?

Use the zoning document prepared for the installation.

Step 1 of 5

Zoning comes from the installation risk assessment. In mixed atmospheres, gas and dust requirements remain separate. A calculated profile does not replace checking the complete assembly certificate.

Understand ATEX zoning and markings ↗

Product sheets

Fans listed in the ATEX catalogue

Open a product sheet to review the characteristics and documents for that reference.

HC

Select a product sheet to view its reference details.

مروحة محورية النوع HC
مراوح محورية

HC

مروحة محورية للدمج في القنوات, غلاف قصير HCC أو طويل HCL مع شفاه توصيل, اقتران مباشر.

عرض بطاقة المنتج
مروحة محورية النوع HC 400°C/2H
سحب الدخان والغازات

HC 400°C/2H

سحب الدخان · تهوية المباني الخدمية غلاف قصير HCC أو طويل HCL مع شفاه توصيل, اقتران مباشر : F400 120 قطر الدفّاعة / المروحة الدافعة : 400– 1600mm التدفق : 0– 170000m3/h الضغط : 0– 110mmCE درجة…

عرض بطاقة المنتج

V-SOD

Select a product sheet to view its reference details.

مروحة طرد مركزي النوع V SOD
مراوح طرد مركزي

V SOD

مروحة طرد مركزي أحادية السحب, دفّاعة بريش منحنية للأمام, ريش مشكّلة بالكبس من النوع TUE , دفع مباشر, غلاف حلزوني بلحام نقطي, من الفولاذ المجلفن, فولاذ مقاوم للصدأ, ألمنيوم.

عرض بطاقة المنتج

VP-SOD

Select a product sheet to view its reference details.

مروحة طرد مركزي النوع VP SOD
مراوح طرد مركزي

VP SOD

مروحة طرد مركزي أحادية السحب, مزود بدافع عالي الكفاءة بريش منحنية للأمام ومركّبة من النوع TURA , دفع مباشر, غلاف حلزوني بلحام نقطي, من الفولاذ المجلفن, فولاذ مقاوم للصدأ, ألمنيوم.

عرض بطاقة المنتج

Roof fans

Select a product sheet to view its reference details.

ساحب هواء سقفي بالطرد المركزي النوع JET
مراوح السطح

JET

أجواء قابلة للانفجار · تهوية صناعية · تهوية المباني الخدمية ساحب هواء سقفي بالطرد المركزي, من البولي بروبيلين, بطرح رأسي قطر الدفّاعة / المروحة الدافعة : 200– 300mm التدفق : 0– 3500m3/h الضغط : 0–…

عرض بطاقة المنتج
ساحب هواء سقفي بالطرد المركزي النوع TE-V
مراوح السطح

TE-V

ساحب هواء سقفي بالطرد المركزي, من الفولاذ المجلفن, فولاذ مقاوم للصدأ … سحب عبر السقف.

عرض بطاقة المنتج
ساحب هواء سقفي بالطرد المركزي النوع TE-VP
مراوح السطح

TE-VP

ساحب هواء سقفي بالطرد المركزي, من الفولاذ المجلفن, فولاذ مقاوم للصدأ … سحب عبر السقف.

عرض بطاقة المنتج

Planning a project?

Send us the details of your installation.

Zone, gas or dust, airflow, pressure, temperature and operating conditions all help define the study.

Discuss my application