INDUSTRIAL VENTILATION · ATEX GUIDE

Does your installation involve an explosive atmosphere?

Flammable gases, vapours or dust: start with the zoning defined for your site. It guides the equipment and marking to be considered.

Understand the essentials

Visual guide

From risk to the right marking

Follow the path: atmosphere, site zone, equipment category, then marking.

AtmosphereGas · vapours · dust
Site zoneDefined by site zoning
CategoryEquipment property
MarkingCheck it in full

Where and when can it occur?

Choose a medium to see its zone scale.

0
Continuous / frequentor long periods
1G
1
Occasionalduring normal operation
1G · 2G
2
Unlikelyand brief if present
1G · 2G · 3G

The zone describes the location. It comes from the installation zoning document.

Which category should you check?

Category = equipment · G = gas · D = dust

1
1G / 1DHighest level of protection
0 · 20
2
2G / 2DEnhanced level
1 · 21
3
3G / 3DFor Zones 2 / 22
2 · 22
2GD · 3GDCombined marking: verify both gas and dust suitability

Important Product sheets below cover Categories 2 and 3. Zones 0 / 20 require Category 1.

Decode a marking

Select a token to understand its role.

II: equipment intended for surface industries.

LEARNING EXAMPLE · INCOMPLETE FRAGMENT

Motor guide

Which motor marking for each zone?

Start with the zone listed in your site documentation, then check the complete motor nameplate and the conditions in its instructions.

Gas · Zone 0Ga

Very high protection is required. A marking limited to Ex db, Ex eb or Ex ec is not sufficient for this zone.

Gas · Zone 1Gb

Ex db: flameproof enclosure. Ex eb: increased safety. These protection types can correspond to EPL Gb when the certificate covers the motor and its use.

Gas · Zone 2Gc

Ex ec: increased safety for EPL Gc. An EPL Gb motor may also be assessed for Zone 2 when the other parameters match.

Ex db IIC T4 Gb — learning example

Select each element: a real nameplate may include other codes and conditions.

Ex: equipment designed according to one or more explosion protection types.

II 2G · Ex db / Ex eb · GbExamples of gas marking to assess for Zone 1. Selection also depends on the gas subgroup and temperature.
II 3G · Ex ec · GcExample of gas marking to assess for Zone 2. EPL Gb may also be assessed when the complete marking is suitable.
Zone 21 → Db · Ex tb | Zone 22 → Dc · Ex tcFor dust, also check group IIIA / IIIB / IIIC, the maximum surface temperature shown in °C and the IP rating. Zone 20 requires EPL Da.
IIA · IIB · IICGas subgroups, to compare with the actual substance. IIC is the most demanding.
T1 ≤450 °C · T2 ≤300 °C · T3 ≤200 °C · T4 ≤135 °C · T5 ≤100 °C · T6 ≤85 °CMaximum surface temperature for gas classes. The higher the T number, the lower the maximum surface temperature.
IIIA · IIIB · IIIC · T°C · IPFor dust: check the group, surface temperature in °C and ingress protection rating together.
Ta / Tamb · X · UTa/Tamb: permitted ambient range. X: special certificate conditions. U: Ex component that must be integrated according to its certificate.

The markings after the protection code matter too. Check gas or dust group, T / °C, Ta or Tamb (ambient), IP, voltage, frequency, speed and inverter use. Certificate suffix X signals specific conditions; U identifies a component rather than complete equipment. Case matters: db is a gas protection type, while Db is a dust EPL. A motor alone does not certify the assembled fan.

Ex eb, Ex db or Ex ec alone is never enough to select a motor: the complete nameplate, certificate, instructions, gas or dust, ambient temperature and fan assembly must match the application. Have the selection confirmed before ordering.

To assess your application
Documented zoneGas / dust identifiedAirflow · pressure · temperatureMarking and product sheet

These visuals provide general guidance: site zoning comes from the risk assessment, and each item’s complete marking must be checked for the application. Prevention guidance (INRS) ↗

Selection assistant

From site zone to fan + motor marking

Answer five steps. The result separates the target marking for the fan and its motor.

  1. 01Atmosphere
  2. 02Zone
  3. 03Substance
  4. 04Motor
  5. 05Result

1. Which atmosphere is listed in the zoning document?

Use the zoning document prepared for the installation.

Step 1 of 5

Zoning comes from the installation risk assessment. In mixed atmospheres, gas and dust requirements remain separate. A calculated profile does not replace checking the complete assembly certificate.

Understand ATEX zoning and markings ↗

Product sheets

Fans listed in the ATEX catalogue

Open a product sheet to review the characteristics and documents for that reference.

HC

Select a product sheet to view its reference details.

Aksialvifte Type HC
Aksialvifter

HC

Aksialvifte for kanalinstallasjon, kort HCC- eller langt HCL-hus med tilkoblingsflenser, direktekobling.

Vis produkt
Aksialvifte Type HC 400°C/2H
Røyk- og gassavsug

HC 400°C/2H

røykavsug · Ventilasjon av næringsbygg kort HCC- eller langt HCL-hus med tilkoblingsflenser, direktekobling : F400 120 Viftehjul- / propelldiameter : 400– 1600mm Luftmengde : 0– 170000m3/h Trykk :…

Vis produkt

V-SOD

Select a product sheet to view its reference details.

Sentrifugalvifte Type V SOD
Sentrifugalvifter

V SOD

Sentrifugalvifte med enkelt innløp, foroverbøyd viftehjul, pressede TUE-skovler, direktedrift, punktsveiset spiralhus, i galvanisert stål, rustfritt stål, aluminium.

Vis produkt

VP-SOD

Select a product sheet to view its reference details.

Sentrifugalvifte Type VP SOD
Sentrifugalvifter

VP SOD

Sentrifugalvifte med enkelt innløp, med høyeffektivt foroverbøyd TURA-viftehjul med monterte skovler, direktedrift, punktsveiset spiralhus, i galvanisert stål, rustfritt stål, aluminium.

Vis produkt

Roof fans

Select a product sheet to view its reference details.

Sentrifugal takvifte Type JET
Takvifter

JET

Eksplosive atmosfærer · Industriventilasjon · Ventilasjon av næringsbygg Sentrifugal takvifte, i polypropylen, vertikalt utblås Viftehjul- / propelldiameter : 200– 300mm Luftmengde : 0– 3500m3/h…

Vis produkt
Sentrifugal takvifte Type TE-V
Takvifter

TE-V

Sentrifugal takvifte, i galvanisert stål, rustfritt stål … Takavsug.

Vis produkt
Sentrifugal takvifte Type TE-VP
Takvifter

TE-VP

Sentrifugal takvifte, i galvanisert stål, rustfritt stål … Takavsug.

Vis produkt